Med Sci Sports Exerc ; 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38465870

RESUMO

INTRODUCTION: Traditional neuromuscular fatigue assessments are not task-specific and are unable to characterize neuromuscular performance decline during dynamic whole-body exercise. This study used interleaved maximal isokinetic cycling efforts to characterize the dynamics of the decline in neuromuscular performance during ramp-incremental (RI) cycle ergometry exercise to intolerance. METHODS: Eleven young healthy participants (10 male/1 female) performed two RI cycle ergometry exercise tests to intolerance: [1] RI-exercise with peak isokinetic power (Piso) at 80 rev·min-1 measured at baseline and immediately at intolerance from a maximal ~6 s effort; [2] RI-exercise where additional Piso measurements were interleaved every 90 s to characterize the decline in neuromuscular performance during the RI-test. Muscle excitation was measured using EMG during all Piso assessments, and pulmonary gas exchange was measured throughout. RESULTS: Baseline Piso was 832 ± 140 W and RI-exercise reduced Piso to 349 ± 96 W at intolerance (p = 0.001), which was not different from flywheel power at intolerance (303 ± 96 W; p = 0.292). There was no reduction in Piso between baseline cycling and gas exchange threshold (GET; baseline Piso vs. mean Piso below GET: 828 ± 146 vs. 815 ± 149 W; p = 1.00). Piso fell progressively above GET until intolerance (Piso every 90 s above GET: 759 ± 139; 684 ± 141; 535 ± 144; 374 ± 117 W; each p < 0.05 vs. baseline and mean Piso below GET). Peak muscle excitation (EMG) was also reduced only above GET (73 ± 14 % of baseline, at intolerance; p < 0.05). However, the reduction in peak Piso preceded the reduction in peak muscle excitation. CONCLUSIONS: The dynamics of the decline in neuromuscular performance (reduction in Piso and EMG) during RI-exercise are consistent with known intensity-dependent metabolic and traditional pre-post neuromuscular fatigue responses to discrete bouts of constant-power exercise.

3.
COPD ; 21(1): 2301549, 2024 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38348843

RESUMO

Exertional dyspnea, a key complaint of patients with chronic obstructive pulmonary disease (COPD), ultimately reflects an increased inspiratory neural drive to breathe. In non-hypoxemic patients with largely preserved lung mechanics - as those in the initial stages of the disease - the heightened inspiratory neural drive is strongly associated with an exaggerated ventilatory response to metabolic demand. Several lines of evidence indicate that the so-called excess ventilation (high ventilation-CO2 output relationship) primarily reflects poor gas exchange efficiency, namely increased physiological dead space. Pulmonary function tests estimating the extension of the wasted ventilation and selected cardiopulmonary exercise testing variables can, therefore, shed unique light on the genesis of patients' out-of-proportion dyspnea. After a succinct overview of the basis of gas exchange efficiency in health and inefficiency in COPD, we discuss how wasted ventilation translates into exertional dyspnea in individual patients. We then outline what is currently known about the structural basis of wasted ventilation in "minor/trivial" COPD vis-à-vis the contribution of emphysema versus a potential impairment in lung perfusion across non-emphysematous lung. After summarizing some unanswered questions on the field, we propose that functional imaging be amalgamated with pulmonary function tests beyond spirometry to improve our understanding of this deeply neglected cause of exertional dyspnea. Advances in the field will depend on our ability to develop robust platforms for deeply phenotyping (structurally and functionally), the dyspneic patients showing unordinary high wasted ventilation despite relatively preserved FEV1.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/complicações , Tolerância ao Exercício/fisiologia , Pulmão , Dispneia/etiologia , Espirometria , Teste de Esforço
4.
Eur J Appl Physiol ; 124(3): 1027-1036, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37803179

RESUMO

PURPOSE: Pathogen transmission during cardio-pulmonary exercise testing (CPET) is caused by carrier aerosols generated during respiration. METHODS: Ten healthy volunteers (age range: 34 ± 15; 4 females) were recruited to see if the physiological reactions to ramp-incremental CPET on a cycle ergometer were affected using an in-line filter placed between the mouthpiece and the flow sensor. The tests were in random order with or without an in-line bacterial/viral spirometer filter. The work rate aligned, time interpolated 10 s bin data were compared throughout the exercise period. RESULTS: From rest to peak exercise, filter use increased only minute ventilation ([Formula: see text]E) (Δ[Formula: see text]E = 1.56 ± 0.70 L/min, P < 0.001) and tidal volume (VT) (ΔVT = 0.10 ± 0.11 L, P = 0.014). Over the entire test, the slope of the residuals for [Formula: see text]CO2 was positive (0.035 ± 0.041 (ΔL/L), P = 0.027). During a ramp-incremental CPET in healthy subjects, an in-line filter increased [Formula: see text]E and VT but not metabolic rate. CONCLUSION: In conclusion, using an in-line filter is feasible, does not affect appreciably the physiological variables, and may mitigate risk of aerosol dispersion during CPET.


Assuntos
Teste de Esforço , Respiração , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Voluntários Saudáveis , Exercício Físico/fisiologia , Volume de Ventilação Pulmonar , Consumo de Oxigênio/fisiologia
5.
Am J Physiol Regul Integr Comp Physiol ; 325(5): R433-R445, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37519253

RESUMO

Identification of the breathing cycle forms the basis of any breath-by-breath gas exchange analysis. Classically, the breathing cycle is defined as the time interval between the beginning of two consecutive inspiration phases. Based on this definition, several research groups have developed algorithms designed to estimate the volume and rate of gas transferred across the alveolar membrane ("alveolar gas exchange"); however, most algorithms require measurement of lung volume at the beginning of the ith breath (VLi-1; i.e., the end-expiratory lung volume of the preceding ith breath). The main limitation of these algorithms is that direct measurement of VLi-1 is challenging and often unavailable. Two solutions avoid the requirement to measure VLi-1 by redefining the breathing cycle. One method defines the breathing cycle as the time between two equal fractional concentrations of lung expired oxygen (Fo2) (or carbon dioxide; Fco2), typically in the alveolar phase, whereas the other uses the time between equal values of the Fo2/Fn2 (or Fco2/Fn2) ratios [i.e., the ratio of fractional concentrations of lung expired O2 (or CO2) and nitrogen (N2)]. Thus, these methods identify the breathing cycle by analyzing the gas fraction traces rather than the gas flow signal. In this review, we define the traditional approach and two alternative definitions of the human breathing cycle and present the rationale for redefining this term. We also explore the strengths and limitations of the available approaches and provide implications for future studies.


Assuntos
Alvéolos Pulmonares , Troca Gasosa Pulmonar , Humanos , Troca Gasosa Pulmonar/fisiologia , Alvéolos Pulmonares/fisiologia , Respiração , Pulmão/fisiologia , Testes Respiratórios , Dióxido de Carbono , Oxigênio
6.
Med Sci Sports Exerc ; 55(10): 1941, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37170926
8.
Med Sci Sports Exerc ; 55(6): 1097-1104, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36633582

RESUMO

INTRODUCTION: Several studies report that pulmonary oxygen uptake (V̇O 2 ) at the respiratory compensation point (RCP) is equivalent to the V̇O 2 at critical power (CP), suggesting that the variables can be used interchangeably to demarcate the threshold between heavy and severe intensity domains. However, if RCP is a valid surrogate for CP, their values should correspond even when assessed in patients with chronic obstructive pulmonary disease (COPD) in whom the "normal" mechanisms linking CP and RCP are impeded. The aim of this study was to compare V̇O 2 at CP with V̇O 2 at RCP in patients with COPD. METHODS: Twenty-two COPD patients (14 male/8 female; forced expiratory volume in 1 s, 46% ± 17% pred) performed ramp-incremental cycle ergometry to intolerance (5-10 W·min -1 ) for the determination of gas exchange threshold (GET) and RCP. CP was calculated from the asymptote of the hyperbolic power-duration relationship from 3-5 constant-power exercise tests to intolerance. CP was validated with a 20-min constant-power ride. RESULTS: GET was identified in 20 of 22 patients at a V̇O 2 of 0.93 ± 0.18 L·min -1 (75% ± 13% V̇O 2peak ), whereas RCP was identified in just 3 of 22 patients at a V̇O 2 of 1.40 ± 0.39 L·min -1 (85% ± 2% V̇O 2peak ). All patients completed constant-power trials with no difference in peak physiological responses relative to ramp-incremental exercise ( P > 0.05). CP was 46 ± 22 W, which elicited a V̇O 2 of 1.04 ± 0.29 L·min -1 (90% ± 9% V̇O 2peak ) during the validation ride. The difference in V̇O 2 at 15 and 20 min of the validation ride was 0.00 ± 0.04 L, which was not different from a hypothesized mean of 0 ( P = 0.856), thereby indicating a V̇O 2 steady state. CONCLUSIONS: In COPD patients, who present with cardiopulmonary and/or respiratory-mechanical dysfunction, CP can be determined in the absence of RCP. Accordingly, CP and RCP are not equivalent in this group.


Assuntos
Ergometria , Doença Pulmonar Obstrutiva Crônica , Humanos , Masculino , Feminino , Teste de Esforço , Exercício Físico/fisiologia , Pulmão , Consumo de Oxigênio/fisiologia
9.
Respir Care ; 68(4): 445-451, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36400446

RESUMO

BACKGROUND: Supplemental oxygen is designed to raise alveolar PO2 to facilitate diffusion into arterial blood. Oxygen is generally delivered by nasal cannula either by continuous or pulsatile flow. Battery-powered portable oxygen concentrators (POCs) facilitate ambulation in patients experiencing exertional hypoxemia. In the United States, the Food and Drug Administration (FDA) clears these devices to be sold by physician prescription. Recently, however, lower-cost devices described as POCs have been advertised by online retailers. These devices lack FDA clearance and are obtained over the counter (OTC) without prescription. This study determined whether a selected group of OTC POCs have oxygen delivery characteristics suitable for use by hypoxemic patients. METHODS: A metabolic simulator, capable of simulating a range of metabolic rates and minute ventilations, determined effects of oxygen supplementation delivered by a variety of devices on alveolar PO2 . Devices tested included 3 OTC POCs, an FDA-cleared POC, and continuous-flow oxygen from a compressed oxygen cylinder. End-tidal PETO2 , a surrogate of alveolar PO2 , was determined at each of each device's flow settings at 3 metabolic rates. RESULTS: Continuous-flow tank oxygen yielded a linear PETO2 increase as flow increased, with progressively lower slope of increase for higher metabolic rate. The prescription POC device yielded similar PETO2 elevations, though with somewhat smaller elevations in pulse-dose operation. One OTC POC was only technically portable (no on-board battery); it provided only modest PETO2 elevation that failed to increase as flow setting was incremented. A second OTC POC produced only minimal PETO2 elevation. A third OTC POC, a pulsed-dose device, produced meaningful PETO2 increases, though not as great as the prescription device. CONCLUSIONS: Only one of 3 OTC POCs tested was potentially of use by patients requiring ambulatory oxygen. Physicians and respiratory therapists should inform patients requiring portable oxygen that OTC devices may not meet their oxygenation requirements.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Doença Pulmonar Obstrutiva Crônica/terapia , Oxigenoterapia , Oxigênio , Pulmão , Fenômenos Fisiológicos Respiratórios
10.
Physiol Rep ; 10(16): e15441, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35986498

RESUMO

BACKGROUND: Menopause represents a turning point where vascular damage begins to outweigh reparative processes, leading to increased cardiovascular disease (CVD) risk. Exercise training reduces CVD risk in postmenopausal females via improvements in traditional risk factors and direct changes to the vasculature. We assessed the effect of moderate (MODERATE-IT) versus heavy (HEAVY-IT) intensity interval exercise training upon markers of cardiovascular health and vascular repair in postmenopausal females. METHODS: Twenty-seven healthy postmenopausal females (56 ± 4 yr) were assigned to 12 weeks of either MODERATE-IT or HEAVY-IT, twice per week. MODERATE-IT consisted of 10s work, and 10s active recovery repeated for 30 min. HEAVY-IT comprised 30s work, and 30s active recovery repeated for 21 ± 2 min. Endothelial function (flow-mediated dilation), arterial stiffness (pulse wave velocity), and V̇O2peak were assessed pre-training and post-training. Blood samples were obtained pre-training and post-training for enumeration of circulating angiogenic cells (CACs), culture of CACs, and lipoprotein profile. RESULTS: V̇O2peak increased 2.4 ± 2.8 ml/kg/min following HEAVY-IT only (p < 0.05). Brachial blood pressure and endothelial function were unchanged with exercise training (p > 0.05). Peripheral pulse wave velocity reduced 8% with exercise training, irrespective of intensity (p < 0.05). Exercise training had no effect on lipoprotein profile or endothelin-1 (p > 0.05). CAC adhesion to vascular smooth muscle cells (VSMC) increased 30 min post plating following MODERATE-IT only (p < 0.05). CONCLUSIONS: HEAVY-IT was more effective at increasing V̇O2peak in postmenopausal females. The ability of CACs to adhere to VSMC improved following MODERATE-IT but not HEAVY-IT. Interval training had the same effect on endothelial function (no change) and arterial stiffness (reduced), regardless of exercise intensity.


Assuntos
Doenças Cardiovasculares , Rigidez Vascular , Endotélio Vascular/fisiologia , Exercício Físico/fisiologia , Feminino , Humanos , Pós-Menopausa , Análise de Onda de Pulso , Rigidez Vascular/fisiologia
12.
Exerc Sport Sci Rev ; 49(4): 274-283, 2021 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-34547760

RESUMO

We hypothesize that the V˙O2 time constant (τV˙O2) determines exercise tolerance by defining the power output associated with a "critical threshold" of intramuscular metabolite accumulation (e.g., inorganic phosphate), above which muscle fatigue and work inefficiency are apparent. Thereafter, the V˙O2 "slow component" and its consequences (increased pulmonary, circulatory, and neuromuscular demands) determine performance limits.


Assuntos
Tolerância ao Exercício , Consumo de Oxigênio , Metabolismo Energético , Teste de Esforço , Humanos , Cinética , Músculo Esquelético/metabolismo
13.
Med Sci Sports Exerc ; 53(8): 1606-1614, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34261991

RESUMO

INTRODUCTION: The mechanism(s) of exercise intolerance at V˙O2max remain poorly understood. In health, standard ramp-incremental (RI) exercise is limited by fatigue-induced reductions in maximum voluntary cycling power. Whether neuromuscular fatigue also limits exercise when the RI rate is slow and RI peak power at intolerance is lower than standard RI exercise, is unknown. METHODS: In twelve healthy participants, maximal voluntary cycling power was measured during a short (~6 s) isokinetic effort at 80 rpm (Piso) at baseline and, using an instantaneous switch from cadence-independent to isokinetic cycling, immediately at the limit of RI exercise with RI rates of 50, 25, and 10 W·min-1 (RI-50, RI-25, and RI-10). Breath-by-breath pulmonary gas exchange was measured throughout. RESULTS: Baseline Piso was not different among RI rates (analysis of variance; P > 0.05). Tolerable duration increased with decreasing RI rate (RI-50, 411 ± 58 s vs RI-25, 732 ± 93 s vs RI-10, 1531 ± 288 s; P < 0.05). At intolerance, V˙O2peak was not different among RI rates (analysis of variance; P > 0.05), but RI peak power decreased with RI rate (RI-50, 361 ± 48 W vs RI-25, 323 ± 39 W vs RI-10, 275 ± 38 W; P < 0.05). Piso at intolerance was 346 ± 43 W, 353 ± 45 W, and 392 ± 69 W for RI-50, RI-25, and RI-10, respectively (P < 0.05 for RI-10 vs RI-50 and RI-25). At intolerance, in RI-50 and RI-25, Piso was not different from RI peak power (P > 0.05), thus there was no "power reserve." In RI-10, Piso was greater than RI peak power at intolerance (P < 0.001), that is, there was a "power reserve." CONCLUSIONS: In RI-50 and RI-25, the absence of a power reserve suggests the neuromuscular fatigue-induced reduction in Piso coincided with V˙O2max and limited the exercise. In RI-10, the power reserve suggests neuromuscular fatigue was insufficient to limit the exercise, and additional mechanisms contributed to intolerance at V˙O2max.


Assuntos
Exercício Físico , Fadiga Muscular , Consumo de Oxigênio , Adulto , Teste de Esforço , Tolerância ao Exercício , Feminino , Humanos , Masculino , Músculo Esquelético/fisiologia , Troca Gasosa Pulmonar , Adulto Jovem
14.
ESC Heart Fail ; 8(2): 898-907, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33609003

RESUMO

AIMS: Heart failure with reduced ejection fraction (HFrEF) induces skeletal muscle mitochondrial abnormalities that contribute to exercise limitation; however, specific mitochondrial therapeutic targets remain poorly established. This study quantified the relationship and contribution of distinct mitochondrial respiratory states to prognostic whole-body measures of exercise limitation in HFrEF. METHODS AND RESULTS: Male patients with HFrEF (n = 22) were prospectively enrolled and underwent ramp-incremental cycle ergometry cardiopulmonary exercise testing to determine exercise variables including peak pulmonary oxygen uptake (V̇O2peak ), lactate threshold (V̇O2LT ), the ventilatory equivalent for carbon dioxide (V̇E /V̇CO2LT ), peak circulatory power (CircPpeak ), and peak oxygen pulse. Pectoralis major was biopsied for assessment of in situ mitochondrial respiration. All mitochondrial states including complexes I, II, and IV and electron transport system (ETS) capacity correlated with V̇O2peak (r = 0.40-0.64; P < 0.05), V̇O2LT (r = 0.52-0.72; P < 0.05), and CircPpeak (r = 0.42-0.60; P < 0.05). Multiple regression analysis revealed that combining age, haemoglobin, and left ventricular ejection fraction with ETS capacity could explain 52% of the variability in V̇O2peak and 80% of the variability in V̇O2LT , respectively, with ETS capacity (P = 0.04) and complex I (P = 0.01) the only significant contributors in the model. CONCLUSIONS: Mitochondrial respiratory states from skeletal muscle biopsies of patients with HFrEF were independently correlated to established non-invasive prognostic cycle ergometry cardiopulmonary exercise testing indices including V̇O2peak , V̇O2LT , and CircPpeak . When combined with baseline patient characteristics, over 50% of the variability in V̇O2peak could be explained by the mitochondrial ETS capacity. These data provide optimized mitochondrial targets that may attenuate exercise limitations in HFrEF.


Assuntos
Insuficiência Cardíaca , Humanos , Masculino , Consumo de Oxigênio , Respiração , Volume Sistólico , Função Ventricular Esquerda
15.
J Appl Physiol (1985) ; 130(2): 421-434, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33356985

RESUMO

In 11 healthy adults (25 ± 4 yr; 2 female, 9 male subjects), we investigated the effect of expiratory resistive loaded breathing [65% maximal expiratory mouth pressure (MEP), 15 breaths·min-1, duty cycle 0.5; ERLPm] on mean arterial pressure (MAP), leg vascular resistance (LVR), and leg blood flow ([Formula: see text]). On a separate day, a subset of five male subjects performed ERL targeting 65% of maximal expiratory gastric pressure (ERLPga). ERL-induced expiratory muscle fatigue was confirmed by a 17 ± 5% reduction in MEP (P < 0.05) and a 16 ± 12% reduction in the gastric twitch pressure response to magnetic nerve stimulation (P = 0.09) from before to after ERLPm and ERLPga, respectively. From rest to task failure in ERLPm and ERLPga, MAP increased (ERLPm = 31 ± 10 mmHg, ERLPga = 18 ± 9 mmHg, both P < 0.05), but group mean LVR and [Formula: see text] were unchanged (ERLPm: LVR = 0.78 ± 0.21 vs. 0.97 ± 0.36 mmHg·mL-1·min, [Formula: see text] = 133 ± 34 vs. 152 ± 74 mL·min-1; ERLPga: LVR = 0.70 ± 0.21 vs. 0.84 ± 0.33 mmHg·mL-1·min, [Formula: see text] = 160 ± 48 vs. 179 ± 110 mL·min-1) (all P ≥ 0.05). Interestingly, [Formula: see text] during ERLPga oscillated within each breath, increasing (∼66%) and decreasing (∼50%) relative to resting values during resisted expirations and unresisted inspirations, respectively. In conclusion, fatiguing expiratory muscle work did not affect group mean LVR or [Formula: see text] in otherwise resting humans. We speculate that any sympathetically mediated peripheral vasoconstriction was counteracted by transient mechanical effects of high intra-abdominal pressures during ERL.NEW & NOTEWORTHY Fatiguing expiratory muscle work in otherwise resting humans elicits an increase in sympathetic motor outflow; whether limb blood flow ([Formula: see text]) and leg vascular resistance (LVR) are affected remains unknown. We found that fatiguing expiratory resistive loaded breathing (ERL) did not affect group mean [Formula: see text] or LVR. However, within-breath oscillations in [Formula: see text] may reflect a sympathetically mediated vasoconstriction that was counteracted by transient increases in [Formula: see text] due to the mechanical effects of high intra-abdominal pressure during ERL.


Assuntos
Fadiga Muscular , Músculos Respiratórios , Adulto , Expiração , Feminino , Humanos , Masculino , Descanso , Resistência Vascular
16.
Quant Imaging Med Surg ; 10(9): 1837-1851, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32879861

RESUMO

BACKGROUND: Cardiovascular magnetic resonance (CMR) image acquisition techniques during exercise typically requires either transient cessation of exercise or complex post-processing, potentially compromising clinical utility. We evaluated the feasibility and reproducibility of a navigated image acquisition method for ventricular volumes assessment during continuous physical exercise. METHODS: Ten healthy volunteers underwent supine cycle ergometer (Lode) exercise CMR on two separate occasions using a free-breathing, multi-shot, navigated, balanced steady-state free precession cine pulse sequence. Images were acquired at 3-stages, baseline and during steady-state exercise at 55% and 75% maximal heart rate (HRmax), based on a prior supine cardiopulmonary exercise test. Intra-and inter-observer variability and inter-scan reproducibility were derived. Clinical feasibility was tested in a separate cohort of patients with severe mitral regurgitation (n=6). RESULTS: End-diastolic volume (EDV) of both LV and RV decreased during exercise at 55% and 75% HRmax, although a reduction in RVEDV index was only observed at 75% HRmax. Ejection fractions (EF) for both ventricles were significantly higher at 75% HRmax compared to their respective baselines (LVEF 68%±3% vs. 58%±5%, P=0.001; RVEF 66%±4% vs. 58%±7%, P=0.02). Intra-observer and inter-observer reproducibility of LV parameters was excellent at all 3-stages. Although measurements of RVESV were more variable during exercise, the reproducibility of both RVEF and RV cardiac index was excellent (CV <10%). Inter-scan LV and RV ejection fraction were highly reproducible at all 3 stages, although inter-scan reproducibility of indexed RVESV was only moderate. The protocol was well tolerated by all patients. CONCLUSIONS: Exercise CMR using a free-breathing, multi-shot, navigated cine imaging method allows simultaneous assessment of left and right ventricular volumes during continuous exercise. Intra- and inter-observer reproducibility were excellent. Inter-scan LV and RV ejection fraction were also highly reproducible.

17.
J Appl Physiol (1985) ; 127(6): 1754-1762, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31600098

RESUMO

Endothelial cell phenotype and endothelial function are regulated by hemodynamic forces, particularly wall shear stress (WSS). During a single bout of exercise, the specific exercise protocol can affect in-exercise WSS patterns and, consequently, endothelial function. MicroRNAs might provide a biomarker of in-exercise WSS pattern to indicate whether a specific exercise bout will have a positive effect on endothelial function. We evaluated the effect of acute interval (IT) and continuous (CON) in-exercise WSS patterns upon postexercise endothelial function and circulating microRNA (miR)-21 expression. Methods and results: 13 participants performed CON and 3 different IT exercise protocols matched for duration and intensity on separate days. Oxygen uptake, heart rate, and brachial artery blood flow were recorded throughout the exercise. Brachial artery flow-mediated dilation (FMD) was performed pre-exercise and 15 min postexercise. Plasma samples were acquired pre-exercise and 6 h postexercise to determine miR-21 expression. In-exercise shear rate (SR) patterns (a surrogate of WSS) differed according to the CON or IT work-rate profile. In-exercise anterograde SR was greater in CON than IT exercise (P < 0.05), but retrograde SR was equivalent between exercise protocols (P > 0.05). Oscillatory shear index was higher during IT versus CON exercise (P < 0.05). Postexercise FMD increased (pre: 7.08% ± 2.95%, post: 10.54% ± 4.24%, P < 0.05), whereas miR-21 expression was unchanged (pre: 12.0% ± 20.7% cel-miR-39, post: 11.1 ± 19.3% cel-miR-39, P > 0.05) with no effect of exercise protocol (P > 0.05). Conclusions: CON and IT exercise induced different SR patterns but equivalent improvements in acute endothelial function. The absence of change in miR-21 expression suggests that miR-21 is not a suitable biomarker of exercise-induced SR.NEW & NOTEWORTHY Interval exercise has the potential to negatively impact vascular adaptations because of repeated oscillations in vascular shear. To our knowledge, we are the first to continuously assess exercise-induced shear throughout different acute exercise protocols and examine its relationship with acute endothelial function and a circulating biomarker of shear (miR-21). These experiments provide clear data indicating enhancement of the acute vascular response from differing interval exercise protocols, with the study also providing detailed vascular and shear responses for future reference.


Assuntos
Endotélio Vascular/metabolismo , Endotélio Vascular/fisiologia , Exercício Físico/fisiologia , MicroRNAs/metabolismo , Adulto , Velocidade do Fluxo Sanguíneo/fisiologia , Artéria Braquial/metabolismo , Artéria Braquial/fisiologia , Feminino , Força da Mão/fisiologia , Frequência Cardíaca/fisiologia , Hemodinâmica/fisiologia , Humanos , Masculino , Fluxo Sanguíneo Regional/fisiologia , Estresse Mecânico , Vasodilatação/fisiologia , Adulto Jovem
18.
Int J Sports Med ; 40(10): 631-638, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31365946

RESUMO

The asymptote of the hyperbolic power-duration relationship, critical power (CP), demarcates sustainable from non-sustainable exercise. CP is a salient parameter within the theoretical framework determining exercise tolerance. However, measuring CP is time consuming - typically 4 constant-power exercise tests to intolerance, or a 3-min all-out sprint is required.To determine whether 30 s of maximal isokinetic cycling, immediately following the limit of tolerance, approximates CP.Fifteen participants (7 women, 8 men, 23±5 yr, 71±12 kg, V̇O2peak 4.39±1.04 L·min-1; 61±9 mL·kg·min-1) completed 4 constant supra-CP exercise tests to intolerance. Each test was followed immediately by a 30 s maximal isokinetic effort at 80 rpm. Mean isokinetic power was compared to the known CP.Mean±SD CP was 159±47 W (CI95 133, 185 W). Maximal isokinetic power immediately following intolerance was greater (p<0.05) than CP in all but one comparison (181±51 vs. 159±47 W; p>0.07). However, this closest estimation, following the longest duration constant-power test, resulted in 21 W of mean bias and wide limits of agreement (±84 W).Isokinetic power measured immediately following intolerance consistently overestimated critical power. Thus, an adjunct of 30 s maximal isokinetic cycling immediately following the limit of tolerance does not approximate critical power.


Assuntos
Teste de Esforço , Tolerância ao Exercício , Resistência Física , Adolescente , Adulto , Feminino , Humanos , Masculino , Força Muscular , Músculo Esquelético/fisiologia , Consumo de Oxigênio , Adulto Jovem
19.
Med Sci Sports Exerc ; 51(8): 1720-1726, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30817712

RESUMO

PURPOSE: We aimed to measure 1) the dynamics of locomotor fatigue during constant supra-critical power cycling and 2) the magnitude of any reserve in locomotor power at intolerance to constant and ramp-incremental cycling in recreationally active volunteers. METHODS: Fifteen participants (7 women and 8 men, 22 ± 3 yr, 3.34 ± 0.67 L·min V˙O2peak) completed ramp-incremental and very-heavy constant power (205 ± 46 W) exercise to the limit of tolerance. Immediately after intolerance, the ergometer was switched into the isokinetic mode, and participants completed a short (~5 s) maximal isokinetic effort at 70 rpm. The time course of locomotor fatigue during constant supra-critical power exercise was characterized with these short maximal isokinetic sprints at 30, 60, 120, and 180 s and at the limit of tolerance. Each bout was terminated after the isokinetic sprint. RESULTS: Constant power exercise duration was 312 ± 37 s. Isokinetic power production values at 30, 60, 120, and 180 s and at the limit of tolerance (at 312 ± 37 s) was 609 ± 165, 503 ± 195, 443 ± 157, 449 ± 133, and 337 ± 94 W, respectively. Of the total decline in isokinetic power, ~36% occurred within the first minute of exercise, and significant (P < 0.05) reductions in isokinetic power occurred at all time points versus the baseline maximal isokinetic power (666 ± 158 W). In addition, a significant power reserve of 132 ± 74 W (64% of the task requirement) and 119 ± 80 W (47%) was present at the limit of constant power and ramp-incremental exercise, respectively. CONCLUSIONS: Locomotor fatigue occurred rapidly during supracritical power exercise with pseudo-exponential kinetics. Instantaneous isokinetic power production at the limit of tolerance exceeded that of the task requirement, regardless of the constant or ramp work rate profile. Thus, the perceptual and physiologic limits were dissociated at the limit of tolerance in recreationally active volunteers.


Assuntos
Ciclismo/fisiologia , Tolerância ao Exercício/fisiologia , Exercício Físico/fisiologia , Fadiga Muscular/fisiologia , Adulto , Teste de Esforço , Feminino , Humanos , Cinética , Masculino , Consumo de Oxigênio/fisiologia , Adulto Jovem